Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Anal Biochem ; 482: 40-7, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25849585

RESUMO

Glycolysis is a 10-step metabolic pathway involved in producing cellular energy. Many tumors exhibit accelerated glycolytic rates, and enzymes that participate in this pathway are focal points of cancer research. Here, a novel method for the measurement of glycolysis reactants from in vitro samples is presented. Fast and direct measurement is achieved by an automated system that couples on-line solid phase extraction (SPE) with tandem mass spectrometry (MS/MS). The single analytical method enables multiple reactants to be measured concurrently, sustains a cycle time of 8s, and permits the measurement of up to 10,000 samples per day. Concentration-response curves were conducted using standards for 10 metabolic intermediates, and the results demonstrate that the detection strategy has excellent sensitivity (average limit of detection = 5.4 nM), dynamic range (nanomolar to micromolar), and linear response (average R(2) = 0.998). To test the analysis method on reactions, pyrophosphate-dependent phosphofructokinase (PPi-PFK) was used as a model system. Data that corroborate the activation and inhibition of PPi-PFK are presented, and the ways in which SPE-MS/MS simplifies experimental design and interpretation are highlighted. In summary, the method for measuring metabolic intermediates described here demonstrates unprecedented speed, performance, and versatility.


Assuntos
Glicólise , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Ensaios de Triagem em Larga Escala/métodos , Humanos , Metabolômica/métodos , Fosfotransferases/metabolismo , Solanum tuberosum/enzimologia , Solanum tuberosum/metabolismo
2.
Metabolites ; 4(3): 655-79, 2014 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-25116756

RESUMO

Mucopolysaccharidoses (MPS) are a group of lysosomal storage disorders caused by deficiency of the lysosomal enzymes essential for catabolism of glycosaminoglycans (GAGs). Accumulation of undegraded GAGs results in dysfunction of multiple organs, resulting in distinct clinical manifestations. A range of methods have been developed to measure specific GAGs in various human samples to investigate diagnosis, prognosis, pathogenesis, GAG interaction with other molecules, and monitoring therapeutic efficacy. We established ELISA, liquid chromatography tandem mass spectrometry (LC-MS/MS), and an automated high-throughput mass spectrometry (HT-MS/MS) system (RapidFire) to identify epitopes (ELISA) or disaccharides (MS/MS) derived from different GAGs (dermatan sulfate, heparan sulfate, keratan sulfate, and/or chondroitin sulfate). These methods have a high sensitivity and specificity in GAG analysis, applicable to the analysis of blood, urine, tissues, and cells. ELISA is feasible, sensitive, and reproducible with the standard equipment. HT-MS/MS yields higher throughput than conventional LC-MS/MS-based methods while the HT-MS/MS system does not have a chromatographic step and cannot distinguish GAGs with identical molecular weights, leading to a limitation of measurements for some specific GAGs. Here we review the advantages and disadvantages of these methods for measuring GAG levels in biological specimens. We also describe an unexpected secondary elevation of keratan sulfate in patients with MPS that is an indirect consequence of disruption of catabolism of other GAGs.

3.
Mol Genet Metab ; 113(1-2): 92-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25092413

RESUMO

Mucopolysaccharidoses (MPS) are caused by deficiency of one of a group of specific lysosomal enzymes, resulting in excessive accumulation of glycosaminoglycans (GAGs). We previously developed GAG assay methods using liquid chromatography tandem mass spectrometry (LC-MS/MS); however, it takes 4-5 min per sample for analysis. For the large numbers of samples in a screening program, a more rapid process is desirable. The automated high-throughput mass spectrometry (HT-MS/MS) system (RapidFire) integrates a solid phase extraction robot to concentrate and desalt samples prior to direction into the MS/MS without chromatographic separation; thereby allowing each sample to be processed within 10s (enabling screening of more than one million samples per year). The aim of this study was to develop a higher throughput system to assay heparan sulfate (HS) using HT-MS/MS, and to compare its reproducibility, sensitivity and specificity with conventional LC-MS/MS. HS levels were measured in the blood (plasma and serum) from control subjects and patients with MPS II, III, or IV and in dried blood spots (DBS) from newborn controls and patients with MPS I, II, or III. Results obtained from HT-MS/MS showed 1) that there was a strong correlation of levels of disaccharides derived from HS in the blood, between those calculated using conventional LC-MS/MS and HT-MS/MS, 2) that levels of HS in the blood were significantly elevated in patients with MPS II and III, but not in MPS IVA, 3) that the level of HS in patients with a severe form of MPS II was higher than that in an attenuated form, 4) that reduction of blood HS level was observed in MPS II patients treated with enzyme replacement therapy or hematopoietic stem cell transplantation, and 5) that levels of HS in newborn DBS were elevated in patients with MPS I, II or III, compared to those of control newborns. In conclusion, HT-MS/MS provides much higher throughput than LC-MS/MS-based methods with similar sensitivity and specificity in an HS assay, indicating that HT-MS/MS may be feasible for diagnosis, monitoring, and newborn screening of MPS.


Assuntos
Heparitina Sulfato/sangue , Ensaios de Triagem em Larga Escala , Espectrometria de Massas , Mucopolissacaridoses/sangue , Mucopolissacaridoses/diagnóstico , Triagem Neonatal , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Pré-Escolar , Cromatografia Líquida , Teste em Amostras de Sangue Seco/métodos , Teste em Amostras de Sangue Seco/normas , Glicosaminoglicanos/sangue , Humanos , Lactente , Recém-Nascido , Triagem Neonatal/métodos , Triagem Neonatal/normas , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Adulto Jovem
4.
J Anal Bioanal Tech ; 2014(Suppl 2): 006, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25068074

RESUMO

Glycosaminoglycans (GAGs) are distributed in the whole body and play a variety of important physiological roles associated with inflammation, growth, coagulation, fibrinolysis, lipolysis, and cell-matrix biology. Accumulation of undegraded GAGs in lysosomes gives rise to a distinct clinical syndrome, mucopolysaccharidoses. Measurement of each specific GAG in a variety of specimens is urgently required to understand GAG interaction with other molecules, physiological status of patients, and prognosis and pathogenesis of the disease. We established a highly sensitive and accurate tandem mass spectrometry (LC-MS/MS) method for measurements of disaccharides derived from four specific GAGs [dermatan sulfate (DS), heparan sulfate (HS), keratan sulfate (KS), and chondroitin sulfate (CS)]. Disaccharides were produced by specific enzyme digestion of each GAG, and quantified by negative ion mode of multiple reaction monitoring. Subclasses of HS and GAGs with identical molecular weights can be separated using a Hypercarbcolumn (2.0 mm×50 mm, 5 µm) with an aectonitrile gradient in ammonium acetate (pH 11.0). We also developed a GAG assay by RapidFire with tandem mass spectrometry (RF-MS/MS). The RF system consists of an integrated solid phase extraction robot that binds and de-salts samples from assay plates and directly injects them into a MS/MS detector, reducing sample processing time to ten seconds. RF-MS/MS consequently yields much faster throughput than conventional LC-MS/MS-based methods. However, the RF system does not have a chromatographic step, and therefore, cannot distinguish GAGs that have identical molecular weights. Both methods can be applied to analysis of dried blood spots, blood, and urine specimens. In this article, we compare the assay methods for GAGs and describe their potential applications.

5.
J Proteome Res ; 11(12): 5642-9, 2012 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-23126378

RESUMO

We investigated the utility of an SPE-MS/MS platform in combination with a modified SISCAPA workflow for chromatography-free MRM analysis of proteotypic peptides in digested human plasma. This combination of SISCAPA and SPE-MS/MS technology allows sensitive, MRM-based quantification of peptides from plasma digests with a sample cycle time of ∼7 s, a 300-fold improvement over typical MRM analyses with analysis times of 30-40 min that use liquid chromatography upstream of MS. The optimized system includes capture and enrichment to near purity of target proteotypic peptides using rigorously selected, high affinity, antipeptide monoclonal antibodies and reduction of background peptides using a novel treatment of magnetic bead immunoadsorbents. Using this method, we have successfully quantitated LPS-binding protein and mesothelin (concentrations of ∼5000 ng/mL and ∼10 ng/mL, respectively) in human plasma. The method eliminates the need for upstream liquid-chromatography and can be multiplexed, thus facilitating quantitative analysis of proteins, including biomarkers, in large sample sets. The method is ideal for high-throughput biomarker validation after affinity enrichment and has the potential for applications in clinical laboratories.


Assuntos
Proteínas Sanguíneas/análise , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas/métodos , Peptídeos/sangue , Software , Proteínas de Fase Aguda/análise , Anticorpos Monoclonais/química , Afinidade de Anticorpos , Biomarcadores/sangue , Proteínas de Transporte/análise , Cromatografia Líquida , Proteínas Ligadas por GPI/sangue , Humanos , Glicoproteínas de Membrana/análise , Mesotelina , Proteômica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
6.
Anal Chem ; 83(21): 8259-66, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21936562

RESUMO

High throughput-solid phase extraction tandem mass spectrometry (HT-SPE/MS) is a fully automated system that integrates sample preparation using ultrafast online solid phase extraction (SPE) with mass spectrometry detection. HT-SPE/MS is capable of conducting analysis at a speed of 5-10 s per sample, which is several fold faster than chromatographically based liquid chromatography-mass spectrometry (LC-MS). Its existing applications mostly involve in vitro studies such as high-throughput therapeutic target screening, CYP450 inhibition, and transporter evaluations. In the current work, the feasibility of utilizing HT-SPE/MS for analysis of in vivo preclinical and clinical samples was evaluated for the first time. Critical bioanalytical parameters, such as ionization suppression and carry-over, were systematically investigated for structurally diverse compounds using generic SPE operating conditions. Quantitation data obtained from HT-SPE/MS was compared with those from LC-MS analysis to evaluate its performance. Ionization suppression was prevalent for the test compounds, but it could be effectively managed by using a stable isotope labeled internal standard (IS). A structural analogue IS also generated data comparable to the LC-MS system for a test compound, indicating matrix effects were also compensated for to some extent. Carry-over was found to be minimal for some compounds and variable for others and could generally be overcome by inserting matrix blanks without sacrificing assay efficiency due to the ultrafast analysis speed. Quantitation data for test compounds obtained from HT-SPE/MS were found to correlate well with those from conventional LC-MS. Comparable accuracy, precision, linearity, and sensitivity were achieved with analysis speeds 20-30-fold higher. The presence of a stable metabolite in the samples showed no impact on parent quantitation for a test compound. In comparison, labile metabolites could potentially cause overestimation of the parent concentration if the ion source conditions are not optimized to minimize in-source breakdown. However, with the use of conditions that minimized in-source conversion, accurate measurement of the parent was achieved. Overall, HT-SPE/MS exhibited significant potential for high-throughput in vivo bioanalysis.


Assuntos
Proteínas Sanguíneas/química , Diclofenaco/análise , Ensaios de Triagem em Larga Escala , Sistemas On-Line , Pirimidinas/análise , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida , Cães , Humanos , Ratos , Padrões de Referência
7.
J Biomol Screen ; 16(10): 1186-95, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21908798

RESUMO

Histone acetyltransferases (HATs) catalyze the transfer of an acetyl group from an acetyl-coenzyme A donor molecule to specific lysine residues within proteins. The acetylation state of proteins, particularly histones, is known to modulate their intermolecular binding properties and control various cellular processes, most notably transcriptional activation. In addition, deregulation of HAT activity has been linked to the development of a number of cancers; therefore, compounds that affect these enzymes have strong potential as therapeutic agents. The research presented here demonstrates three label-free HAT screening approaches, all based on the fast and direct measurement of one or more substrate-product pairs by high-throughput mass spectrometry techniques. The first approach involves monitoring all possible acetylation states of a peptide concurrently to measure HAT activity. The second approach measures acetylation reactions, on both peptides and whole protein substrates, via direct detection of the acetyl-coenzyme A cosubstrate and coenzyme A coproduct. Lastly, the authors demonstrate the ability to monitor directly the acetylation state of whole histone proteins in the same high-throughput manner using time-of-flight mass spectrometry. The generation of compound-mediated inhibition data using each of these techniques establishes mass spectrometry as a versatile, label-free, and biologically relevant screening approach to this challenging target class.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Histona Acetiltransferases/metabolismo , Acetilação/efeitos dos fármacos , Ativação Enzimática/efeitos dos fármacos , Histonas/química , Espectrometria de Massas , Peptídeos/farmacologia , Proteína Supressora de Tumor p53/química , Fatores de Transcrição de p300-CBP/metabolismo
8.
J Biomol Screen ; 16(10): 1217-26, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21911826

RESUMO

The sirtuin enzymes, a class of NAD(+)-dependent histone deacetylases, are a focal point of epigenetic research because of their roles in regulating gene expression and cellular differentiation by deacetylating histones and a host of transcription factors, including p53. Here, the authors present two label-free screening methodologies to study sirtuin activity using high-throughput mass spectrometry. The first method involves the detection of native peptides and provides a platform for more detailed mechanistic studies by enabling the concurrent and direct measurement of multiple modification states. The second method obviates the need for substrate-specific assay development by measuring the O-acetyl-ADP-ribose co-product formed by sirtuin-dependent deacetylation. Both methodologies were applied to investigating the deacetylation of multiple-peptide substrates by multiple-sirtuin enzymes. Kinetic data, including binding constants, inhibition, and, in some cases, activation, are demonstrated to correlate well, both between the methodologies and with previous literature precedent. In addition, the ability to monitor sirtuin activity via O-acetyl-ADP-ribose production permits experimentation on whole-protein substrates. The deacetylation of whole-histone proteins by SIRT3, and inhibition thereof, is presented and demonstrates the feasibility of screening sirtuins using more biologically relevant molecules.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Sirtuínas/análise , Sirtuínas/metabolismo , Acetilação/efeitos dos fármacos , Histonas/química , Humanos , Cinética , Espectrometria de Massas , O-Acetil-ADP-Ribose/análise , O-Acetil-ADP-Ribose/metabolismo , Peptídeos/farmacologia , Proteína Supressora de Tumor p53/química
9.
J Biomol Screen ; 16(2): 272-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21297110

RESUMO

To facilitate discovery of compounds modulating sphingosine-1-phosphate (S1P) signaling, the authors used high-throughput mass spectrometry technology to measure S1P formation in human whole blood. Since blood contains endogenous sphingosine (SPH) and S1P, mass spectrometry was chosen to detect the conversion of an exogenously added 17-carbon-long variant of sphingosine, C17SPH, into C17S1P. The authors developed procedures to achieve homogeneous mixing of whole blood in 384-well plates and for a method requiring minimal manipulations to extract S1P from blood in 96- and 384-well plates prior to analyses using the RapidFire(®) mass spectrometry system.


Assuntos
Inibidores Enzimáticos/sangue , Ensaios de Triagem em Larga Escala , Espectrometria de Massas , Fosfotransferases (Aceptor do Grupo Álcool)/antagonistas & inibidores , Fosfotransferases (Aceptor do Grupo Álcool)/metabolismo , Aminofenóis/metabolismo , Aminofenóis/farmacologia , Relação Dose-Resposta a Droga , Humanos , Cinética , Lisofosfolipídeos/metabolismo , Transdução de Sinais/efeitos dos fármacos , Esfingosina/análogos & derivados , Esfingosina/metabolismo , Tiazóis/metabolismo , Tiazóis/farmacologia
10.
J Biomol Screen ; 15(1): 52-61, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20019290

RESUMO

A high-throughput mass spectrometry assay to measure the catalytic activity of UDP-3-O-(R-3-hydroxymyristoyl)-N-acetylglucosamine deacetylase, LpxC, is described. This reaction is essential in the biosynthesis of lipopolysaccharide (LPS) of gram-negative bacteria and is an attractive target for the development of new antibacterial agents. The assay uses the RapidFire mass spectrometry platform to measure the native LpxC substrate and the reaction product and thereby generates a ratiometric readout with minimal artifacts due to detection interference. The assay was robust in a high-throughput screen of a library of more than 700,000 compounds arrayed as orthogonal mixtures, with a median Z' factor of 0.74. Selected novel inhibitors from the screening campaign were confirmed as binding to LpxC by biophysical measurements using a thermal stability shift assay. Some inhibitors showed whole-cell antimicrobial activity against a sensitive strain of Escherichia coli with reduced LpxC activity (strain D22; minimum inhibitory concentrations ranging from 0.625-20 microg/mL). The results show that mass spectrometry-based screening is a valuable high-throughput screening tool for detecting inhibitors of enzymatic targets involving difficult to detect reactions.


Assuntos
Amidoidrolases/antagonistas & inibidores , Antibacterianos/análise , Inibidores Enzimáticos/análise , Inibidores Enzimáticos/farmacologia , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas/métodos , Antibacterianos/química , Antibacterianos/farmacologia , Dimetil Sulfóxido/farmacologia , Inibidores Enzimáticos/química , Estabilidade Enzimática/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Fluorescência , Testes de Sensibilidade Microbiana , Reprodutibilidade dos Testes , Bibliotecas de Moléculas Pequenas/análise , Bibliotecas de Moléculas Pequenas/farmacologia , Especificidade por Substrato/efeitos dos fármacos , Temperatura
11.
Assay Drug Dev Technol ; 7(5): 495-506, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19715455

RESUMO

Label-free mass spectrometric (MS) technologies are particularly useful for enzyme assay design for drug discovery screens. MS permits the selective detection of enzyme substrates or products in a wide range of biological matrices without need for derivatization, labeling, or capture technologies. As part of a cardiovascular drug discovery effort aimed at finding modulators of cystathionine beta-synthase (CBS), we used the RapidFire((R)) label-free high-throughput MS (HTMS) technology to develop a high-throughput screening (HTS) assay for CBS activity. The in vitro assay used HTMS to quantify the unlabeled product of the CBS reaction, cystathionine. Cystathionine HTMS analyses were carried out with a throughput of 7 s per sample and quantitation over a linear range of 80-10,000 nM. A compound library of 25,559 samples (or 80 384-well plates) was screened as singlets using the HTMS assay in a period of 8 days. With a hit rate of 0.32%, the actives showed a 90% confirmation rate. The in vitro assay was applied to secondary screens in more complex matrices with no additional analytical development. Our results show that the HTMS method was useful for screening samples containing serum, for cell-based assays, and for liver explants. The novel extension of the in vitro analytical method, without modification, to secondary assays resulted in a significant and advantageous economy of development time for the drug discovery project.


Assuntos
Cistationina/análise , Descoberta de Drogas/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Animais , Calibragem , Linhagem Celular , Cromatografia Líquida de Alta Pressão , Interpretação Estatística de Dados , Relação Dose-Resposta a Droga , Humanos , Indicadores e Reagentes , Cinética , Espectrometria de Massas , Camundongos , Camundongos Endogâmicos C57BL , Espectrometria de Massas por Ionização por Electrospray
12.
Comb Chem High Throughput Screen ; 12(8): 752-9, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19531010

RESUMO

In this review various technologies and approaches for the utilization of mass spectrometry in high-throughput analyses are discussed. The use of quadrupole-based mass spectrometry in the screening of chemical libraries against enzymatic targets for the identification of inhibitors and/or activators is highlighted. The RapidFire mass spectrometry system, an integrated on-line solid-phase extraction system interfaced to a triple-quadrupole mass spectrometer is described in detail, and the identification of a series of inhibitors of the acetyl-coenzyme A carboxylase (ACC) assay is described.


Assuntos
Acetil-CoA Carboxilase/antagonistas & inibidores , Acetil-CoA Carboxilase/metabolismo , Inibidores Enzimáticos/análise , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas/métodos , Descoberta de Drogas , Inibidores Enzimáticos/química , Inibidores Enzimáticos/farmacologia , Extração em Fase Sólida
13.
Anal Chim Acta ; 627(1): 105-11, 2008 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-18790133

RESUMO

Several recent reports suggest that stearoyl-CoA desaturase 1 (SCD1), the rate-limiting enzyme in monounsaturated fatty acid synthesis, plays an important role in regulating lipid homeostasis and lipid oxidation in metabolically active tissues. As several manifestations of type 2 diabetes and related metabolic disorders are associated with alterations in intracellular lipid partitioning, pharmacological manipulation of SCD1 activity might be of benefit in the treatment of these disease states. In an effort to identify small molecule inhibitors of SCD1, we have developed a mass spectrometry based high-throughput screening (HTS) assay using deuterium labeled stearoyl-CoA substrate and induced rat liver microsomes. The methodology developed allows the use of a nonradioactive substrate which avoids interference by the endogenous SCD1 substrate and/or product that exist in the non-purified enzyme source. Throughput of the assay was up to twenty 384-well assay plates per day. The assay was linear with protein concentration and time, and was saturable for stearoyl-CoA substrate (K(m)=10.5 microM). The assay was highly reproducible with an average Z' value=0.6. Conjugated linoleic acid and sterculic acid, known inhibitors of SCD1, exhibited IC(50) values of 0.88 and 0.12 microM, respectively. High-throughput mass spectrometry screening of over 1.7 million compounds in compressed format demonstrated that the enzyme target is druggable. A total of 2515 hits were identified (0.1% hit rate), and 346 were confirmed active (>40% inhibition of total SCD activity at 20 microM--14% conformation rate). Of the confirmed hits 172 had IC(50) values of <10 microM, including 111 <1 microM and 48 <100 nM. A large number of potent drug-like (MW<450) hits representing six different chemical series were identified. The application of mass spectrometry to high-throughput screening permitted the development of a high-quality screening protocol for an otherwise intractable target, SCD1. Further medicinal chemistry and characterization of SCD inhibitors should lead to the development of reagents to treat metabolic disorders.


Assuntos
Acil Coenzima A/metabolismo , Deutério/metabolismo , Avaliação Pré-Clínica de Medicamentos/métodos , Inibidores Enzimáticos/farmacologia , Microssomos Hepáticos/enzimologia , Estearoil-CoA Dessaturase/antagonistas & inibidores , Animais , Ciclopropanos/farmacologia , Citocromo-B(5) Redutase/metabolismo , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/enzimologia , Ácidos Graxos Monoinsaturados/farmacologia , Humanos , Modelos Lineares , Ácidos Linoleicos Conjugados/farmacologia , Masculino , Espectrometria de Massas , Microssomos Hepáticos/efeitos dos fármacos , Ratos , Bibliotecas de Moléculas Pequenas/farmacologia , Coloração e Rotulagem , Estearoil-CoA Dessaturase/metabolismo , Especificidade por Substrato , Fatores de Tempo
14.
J Biomol Screen ; 12(5): 628-34, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17478478

RESUMO

A high-throughput mass spectrometry assay to measure the catalytic activity of phosphatidylserine decarboxylase (PISD) is described. PISD converts phosphatidylserine to phosphatidylethanolamine during lipid synthesis. Traditional methods of measuring PISD activity are low throughput and unsuitable for the high-throughput screening of large compound libraries. The high-throughput mass spectrometry assay directly measures phosphatidylserine and phosphatidylethanolamine using the RapidFiretrade mark platform at a rate of 1 sample every 7.5 s. The assay is robust, with an average Z' value of 0.79 from a screen of 9920 compounds. Of 60 compounds selected for confirmation, 54 are active in dose-response studies. The application of high-throughput mass spectrometry permitted a high-quality screen to be performed for an otherwise intractable target.


Assuntos
Carboxiliases/antagonistas & inibidores , Inibidores Enzimáticos/farmacologia , Espectrometria de Massas/métodos , Carboxiliases/análise , Carboxiliases/genética , Linhagem Celular , Relação Dose-Resposta a Droga , Avaliação Pré-Clínica de Medicamentos , Estabilidade Enzimática , Congelamento , Humanos , Rim/citologia , Cinética , Plasmídeos , Proteínas Recombinantes de Fusão/antagonistas & inibidores , Robótica , Análise de Sequência de DNA , Transfecção
15.
J Biomol Screen ; 12(4): 473-80, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17478485

RESUMO

Mass spectrometry is an emerging format for label-free high-throughput screening. The main limitation of mass spectrometry is throughput, due to the requirement to purify samples prior to ionization. Here the authors compare an automated high-throughput mass spectrometry (HTMS) system (RapidFire) with the scintillation proximity assay (SPA). The cancer therapy target AKT1/PKBalpha was screened against a focused library of kinase inhibitors and IC50 values determined for all compounds that exhibit > 50% inhibition. A selection of additional compounds that exhibited

Assuntos
Proteínas Proto-Oncogênicas c-akt/antagonistas & inibidores , Proteínas Proto-Oncogênicas c-akt/isolamento & purificação , Contagem de Cintilação , Espectrometria de Massas por Ionização por Electrospray , Sequência de Aminoácidos , Reações Falso-Negativas , Reações Falso-Positivas , Dados de Sequência Molecular , Inibidores de Proteínas Quinases/farmacologia , Proteínas Proto-Oncogênicas c-akt/química
16.
Antimicrob Agents Chemother ; 51(1): 119-27, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17074800

RESUMO

The anilinouracils (AUs) such as 6-(3-ethyl-4-methylanilino)uracil (EMAU) are a novel class of gram-positive, selective, bactericidal antibacterials which inhibit pol IIIC, the gram-positive-specific replicative DNA polymerase. We have linked various fluoroquinolones (FQs) to the N-3 position of EMAU to generate a variety of AU-FQ "hybrids" offering the potential for targeting two distinct steps in DNA replication. In this study, the properties of a hybrid, "251D," were compared with those of representative AUs and FQs in a variety of in vitro assays, including pol IIIC and topoisomerase/gyrase enzyme assays, antibacterial, bactericidal, and mammalian cytotoxicity assays. Compound 251D potently inhibited pol IIIC and topoisomerase/gyrase, displayed gram-positive antibacterial potency at least 15 times that of the corresponding AU compound, and as expected, acted selectively on bacterial DNA synthesis. Compound 251D was active against a broad panel of antibiotic-resistant gram-positive pathogens as well as several gram-negative organisms and was also active against both AU- and FQ-resistant gram-positive organisms, demonstrating its capacity for attacking both of its potential targets in the bacterium. 251D also was bactericidal for gram-positive organisms and lacked toxicity in vitro. Although we obtained strains of Staphylococcus aureus resistant to the individual parent compounds, spontaneous resistance to 251D was not observed. We obtained 251D resistance in multiple-passage experiments, but resistance developed at a pace comparable to those for the parent compounds. This class of AU-FQ hybrids provides a promising new pharmacophore with an unusual dual mechanism of action and potent activity against antibiotic-sensitive and -resistant gram-positive pathogens.


Assuntos
Compostos de Anilina/farmacologia , Antibacterianos/farmacologia , Fluoroquinolonas/farmacologia , Bactérias Gram-Positivas/efeitos dos fármacos , Compostos de Anilina/química , Antibacterianos/química , Bacillus/efeitos dos fármacos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , DNA Polimerase III/antagonistas & inibidores , Relação Dose-Resposta a Droga , Farmacorresistência Bacteriana , Enterococcus/efeitos dos fármacos , Fluoroquinolonas/química , Bactérias Gram-Negativas/efeitos dos fármacos , Humanos , Testes de Sensibilidade Microbiana , Viabilidade Microbiana/efeitos dos fármacos , Staphylococcus/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Relação Estrutura-Atividade , Inibidores da Topoisomerase II , Uracila/análogos & derivados , Uracila/química , Uracila/farmacologia
17.
J Med Chem ; 49(4): 1455-65, 2006 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-16480282

RESUMO

Novel Gram-positive (Gram+) antibacterial compounds consisting of a DNA polymerase IIIC (pol IIIC) inhibitor covalently connected to a topoisomerase/gyrase inhibitor are described. Specifically, 3-substituted 6-(3-ethyl-4-methylanilino)uracils (EMAUs) in which the 3-substituent is a fluoroquinolone moiety (FQ) connected by various linkers were synthesized. The resulting "AU-FQ" hybrid compounds were significantly more potent than the parent EMAU compounds as inhibitors of pol IIIC and were up to 64-fold more potent as antibacterials in vitro against Gram+ bacteria. The hybrids inhibited the FQ targets, topoisomerase IV and gyrase, with potencies similar to norfloxacin but 10-fold lower than newer agents, for example, ciprofloxacin and sparfloxacin. Representative hybrids protected mice from lethal Staphylococcus aureus infection after intravenous dosing, and one compound showed protective effect against several antibiotic-sensitive and -resistant Gram+ infections in mice. The AU-FQ hybrids are a promising new family of antibacterials for treatment of antibiotic-resistant Gram+ infections.


Assuntos
Compostos de Anilina/síntese química , Antibacterianos/síntese química , DNA Polimerase III/antagonistas & inibidores , Bactérias Gram-Positivas/efeitos dos fármacos , Inibidores da Topoisomerase II , Uracila/análogos & derivados , Uracila/síntese química , Compostos de Anilina/farmacocinética , Compostos de Anilina/farmacologia , Animais , Antibacterianos/farmacocinética , Antibacterianos/farmacologia , Farmacorresistência Bacteriana , Masculino , Camundongos , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus/efeitos dos fármacos , Relação Estrutura-Atividade , Testes de Toxicidade Aguda , Uracila/farmacocinética , Uracila/farmacologia
18.
J Med Chem ; 48(22): 7063-74, 2005 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-16250666

RESUMO

Numerous 3-substituted-6-(3-ethyl-4-methylanilino)uracils (EMAU) have been synthesized and screened for their capacity to inhibit the replication-specific bacterial DNA polymerase IIIC (pol IIIC) and the growth of Gram+ bacteria in culture. Direct alkylation of 2-methoxy-6-amino-4-pyrimidone produced the N3-substituted derivatives, which were separated from the byproduct 4-alkoxy analogues. The N3-substituted derivatives were heated with a mixture of 3-ethyl-4-methylaniline and its hydrochloride to effect displacement of the 6-amino group and simultaneous demethylation of the 2-methoxy group to yield target compounds in good yields. Certain intermediates, e.g. the 3-(iodoalkyl) compounds, were converted to a variety of (3-substituted-alkyl)-EMAUs by displacement. Most compounds were potent competitive inhibitors of pol IIIC (K(i)s 0.02-0.5 microM), and those with neutral, moderately polar 3-substituents had potent antibacterial activity against Gram+ organisms in culture (MICs 0.125-10 microg/mL). Several compounds protected mice from lethal intraperitoneal (ip) infections with S. aureus (Smith) when given by the ip route. A water soluble derivative, 3-(4-morpholinylbutyl)-EMAU hydrochloride, given subcutaneously, prolonged the life of infected mice in a dose dependent manner.


Assuntos
Compostos de Anilina/síntese química , Antibacterianos/síntese química , DNA Polimerase III/antagonistas & inibidores , Bactérias Gram-Positivas/efeitos dos fármacos , Uracila/análogos & derivados , Uracila/síntese química , Compostos de Anilina/química , Compostos de Anilina/farmacologia , Animais , Antibacterianos/química , Antibacterianos/farmacologia , Camundongos , Testes de Sensibilidade Microbiana , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus , Relação Estrutura-Atividade , Uracila/química , Uracila/farmacologia
19.
Assay Drug Dev Technol ; 2(4): 373-81, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15357918

RESUMO

Mass spectrometry-based screening can be applied to a wide range of targets, including those intractable targets that use substrates such as lipids, fatty acids, phospholipids, steroids, prostaglandins, and other compounds not generally amenable to conventional screening techniques. The major limitation to this approach is throughput, making HTS via mass spectrometry impractical. We present a mass spectrometry-based technique and hardware for lead discovery applications. Mass spectrometry enables the design of label-free assays using biologically native substrates for a wide range of enzymatic targets. This system can be used for the direct quantification of analytes in complex reaction mixtures with typical throughputs of 4-5 s per sample. A mass spectrometry-based assay was developed to identify inhibitors of acetylcholinesterase, an enzyme with clinical importance in Alzheimer's disease. The system was used to screen a small chemical library. Several potent inhibitors were identified, and the IC(50) values of the inhibitors were determined.


Assuntos
Acetilcolinesterase/análise , Acetilcolinesterase/metabolismo , Técnicas Analíticas Microfluídicas/métodos , Inibidores da Colinesterase/química , Inibidores da Colinesterase/farmacologia , Humanos , Concentração Inibidora 50 , Espectrometria de Massas/métodos , Técnicas Analíticas Microfluídicas/instrumentação
20.
Protein Expr Purif ; 29(2): 259-64, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12767818

RESUMO

Bacillus subtilis Bs gyrA and gyrB genes specifying the DNA gyrase subunits, and parC and parE genes specifying the DNA topoisomerase IV subunits, have been separately cloned and expressed in Escherichia coli as hexahistidine (his6)-tagged recombinant proteins. Purification of the gyrA and gyrB subunits together resulted in predominantly two bands at molecular weights of 94 and 73kDa; purification of the parC and parE subunits together resulted in predominantly two bands at molecular weights of 93 and 75kDa, as predicted by their respective sequences. The ability of the subunits to complement their partner was tested in an ATP-dependent decatenation/supercoiling assay system. The results demonstrated that the DNA gyrase and the topoisomerase IV subunits produce the expected supercoiled DNA and relaxed DNA products, respectively. Additionally, inhibition of these two enzymes by fluoroquinolones has been shown to be comparable to those of the DNA gyrases and topoisomerases of other bacterial strains. In sum, the biological and enzymatic properties of these products are consistent with their authenticity as DNA gyrase and DNA topoisomerase IV enzymes from B. subtilis.


Assuntos
Bacillus subtilis/enzimologia , DNA Girase/biossíntese , DNA Girase/genética , DNA Topoisomerase IV/biossíntese , DNA Topoisomerase IV/genética , Bacillus subtilis/genética , Clonagem Molecular , Dano ao DNA , DNA Girase/metabolismo , Primers do DNA/genética , Reparo do DNA , DNA Topoisomerase IV/antagonistas & inibidores , DNA Topoisomerase IV/metabolismo , Inibidores Enzimáticos/farmacologia , Fluoroquinolonas/farmacologia , Concentração Inibidora 50 , Peso Molecular , Proteínas Recombinantes/antagonistas & inibidores , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Inibidores da Topoisomerase II
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...